Three Gang Moulds 40x40x160 mm, EN 196-1

Used to produce the mortar specimens for compression and flexural tests. Made from special alloy steel, they are proposed in two version: Standard 65-L0010/A having a minimum surface hardness of HV200 and Heavy duty 65-L0010/B having a minimum surface hardness of HV400 which is recommended by the EN standards. Furthermore, this model is surface protected by a rust inhibitor treatment and is supplied complete with traceable certificate of conformity and identified by a serial number. Both models can be fit with the 65-L0010/5 type B measuring pegs for determining the coefficient of thermal expansion conforming to EN 1770. See accessories. Weight approx.: 10.9 kg
  • Highlights
  • Features
  • Specification
  • Models
  • Standards
  • Review (2)

Three Gang Moulds 40x40x160 mm, EN 196-1 Price in Bangladesh

Three Gang Moulds are designed for preparing consistent cement mortar specimens, and the Three Gang Moulds 40x40x160 mm, EN 196-1 Price in Bangladesh is widely searched by laboratories and professionals who need reliable cement testing equipment. This mould is manufactured according to professional testing requirements to ensure accurate specimen preparation for strength and quality evaluation.

Made from high-quality materials, this three gang mould provides excellent durability and stability during laboratory operations. Its robust construction helps maintain accurate specimen dimensions and supports repeatable testing results. The design allows efficient sample preparation while reducing errors during cement mortar testing procedures.

This EN 196-1 compliant mould is commonly used in construction material laboratories, research facilities, universities, and quality control departments. It is suitable for preparing cement mortar samples required for testing strength characteristics and material performance. The precise manufacturing process ensures smooth operation and long-lasting usability in demanding laboratory environments.

The Three Gang Mould offers convenient handling and reliable performance for technicians and engineers involved in cement testing. Its strong structure helps maintain alignment and consistency throughout the specimen preparation process, making it an essential tool for professional laboratory applications.

Selecting a high-quality Three Gang Mould improves testing efficiency and supports accurate analysis of cement-based materials. With its durable design, precise construction, and compatibility with standard testing procedures, this mould is an ideal choice for laboratories focused on achieving dependable and consistent testing outcomes.

  • Individually checked with certified instruments
  • All parts marked and identified
  • Model 65-L0010/B has a minimum surface hardness of HV 400 and is surface protected with a rust inhibitor treatment. Supplied complete with traceable certificate of conformity.
  • Both models can be fit with 65-L0010/5 pegs for determining the coefficient of thermal expansion conforming to EN 1770

Notes for proper use of molds:
The list below is by no means exhaustive but wants to give some recommendations for correct use of molds. For more information, please always refer to the user manual.

  • Molds must be kept clean and free from residues. This is essential to extend the lifespan of the molds and prevent any defects on sample surfaces. Clean the molds of any residues within 24 hours after demolding to prevent encrustations.
  • Before casting, it is strongly recommended coat the internal mold faces with a thin layer of a demolding agent (e.g. cod. C0139/A) that facilitates removal of hardened samples during demolding operations.

Notes for proper use of molds:
The list below is by no means exhaustive but wants to give some recommendations for correct use of molds. For more information, please always refer to the user manual.

  • Molds must be kept clean and free from residues. This is essential to extend the lifespan of the molds and prevent any defects on sample surfaces. Clean the molds of any residues within 24 hours after demolding to prevent encrustations and rust.
  • Before casting, it is strongly recommended coat the internal mold faces with a thin layer of a demolding agent (e.g. cod. C0139/A) that facilitates removal of hardened samples during demolding operations.

Code

  • 65-L0010/A
  • 65-L0010/B

Description

  • Three gang mould 40 x 40 x 160 mm according to EN 196-1
  • 40x40x160 mm three gang for mortar prism. Min. hardeness HV400. Complete with traceable certifi- cate for the EN 196 properties and rust inibitor treatment.
  • EN 1770
  • EN 196-1
  • EN 196-3
  • EN 413-2
  • EN 459-2
  • EN 480-1

2 Reviews For win Your Friends

Add Your Review

Your Rating:
Steven Rich – Sep 17, 2016:
How all this mistaken idea of denouncing pleasure and praising pain was born and I will give you a complete account of the system, and expound the actual teachings.
William Cobus – Aug 21, 2016:
There anyone who loves or pursues or desires to obtain pain itself, because it is pain sed, because occasionally circumstances occur some great pleasure.

Any question about the Three Gang Moulds 40x40x160 mm, EN 196-1 ?

* indicates required fields

CAPTCHA